| Type | Power Rating (at70°C) |
Resistance Range | Maximum Working Voltage* |
Maximum Overload Voltage** |
|
| ±1% | ±5% | ||||
| HVR25 | 1/4W | 91KΩ~24MΩ | 1.6KV DC 1150V RMS |
3KV DC 2KV RMS |
|
| HVR50 | 1/2W | 100KΩ~33MΩ | 3.5KV DC 2.5KV RMS |
7KV DC 5KV RMS |
|
| HVR100 | 1W | 100KΩ~68MΩ | 10KV DC 7KV RMS |
20KV DC 14KV RMS |
|
| HVR200 | 2W | 100KΩ~100MΩ | 11KV DC 8KV RMS |
20KV DC 15KV RMS |
|
| HVR300 | 3W | 100KΩ~100MΩ | 12KV DC 8.5KV RMS |
20KV DC 15KV RMS |
|
For a better life cycle under normal usage, 50% of the rated power is recommended
* Rated Continuous Maximum Working Voltage (RCWV) should be determined from RCWV =√Power Rating x Resistance Values Max. RCWV listed above.
** Short-time Overload (STOL) test should be determined from STOL=√2.5 x Power Rating x Resistance Values or maximum overload voltage listed above, whichever is lower.
| Characteristics | Ranges & Limits | |
| Operating Temperature Range, °C | -55 ~ +125 | |
| Temperature Coefficient, PPM / °C* | ±1%, ±2% | ±15, ±25, ±50, ±100 |
| ±5% | ±100 | |
| Dielectric Withstanding Voltage, VAC or DC | MM16, MM204 | 200 |
| MM207, MM52 | 500 | |
| Insulation Resistance, MΩ | >104 | |
| Tin Whisker (JESD201 Temperature Cycling & High Temp. / Humidity Storage), μm |
<5 | |
| Failure Rate in Time, pcs / 109device hours | <1 | |
Not applicable to all resistance values. Please check with us regarding the PPM of specific resistance value(s).
Copyright © 2025.深圳市硕为科技有限公司.备案号:粤ICP备号14036095