![]() |
| Type | Power Rating (at70°C) | Resistance Range | Maximum Working Voltage* |
Maximum Overload Voltage** |
|
| ±1% | ±5% | ||||
| SWA01 | 1W | - |
0.1Ω~10Ω |
√(PxR) | 2.5x√(PxR) |
| 11Ω~1.2KΩ |
|||||
| SWA02 | 2W | - |
0.1Ω~10Ω |
√(PxR) | 2.5x√(PxR) |
| 11Ω~1.2KΩ |
|||||
| SWA03 | 3W | - |
0.1Ω~10Ω |
√(PxR) | 2.5x√(PxR) |
| 11Ω~1.2KΩ |
|||||
| SWA05 | 5W | - |
0.1Ω~10Ω |
√(PxR) | 2.5x√(PxR) |
| 11Ω~1.2KΩ |
|||||
| SWA06 | 6W | - |
0.1Ω~10Ω |
√(PxR) | 2.5x√(PxR) |
| 11Ω~1.2KΩ |
|||||
For a better life cycle under normal usage, 50% of the rated power is recommended
* Rated Continuous Maximum Working Voltage (RCWV) should be determined from RCWV =√Power Rating x Resistance Values Max. RCWV listed above.
** Short-time Overload (STOL) test should be determined from STOL=√2.5 x Power Rating x Resistance Values or maximum overload voltage listed above, whichever is lower.
Copyright © 2025.深圳市硕为科技有限公司.备案号:粤ICP备号14036095